The Basics: How Alkaline Lysis Works

Alkaline lysis was first described by Birnboim and Doly in 1979 (Nucleic Acids Res. 7, 1513-1523) and has, with a few modifications, been the preferred method for plasmid DNA extraction from bacteria ever since. The easiest way to describe how alkaline lysis works is to go through the procedure and explain each step, so here goes.
1. Cell Growth and Harvesting
The procedure starts with the growth of the bacterial cell culture harboring your plasmid. When sufficient growth has been achieved, the cells are pelleted by centrifugation to remove them from the growth medium.
2. Re-suspension
The pellet is then re-suspended in a solution (normally called solution I, or similar in the kits) containing Tris, EDTA, glucose and RNase A. Divalent cations (Mg2+, Ca2+) are essential for DNase activity and the integrity of the bacterial cell wall. EDTA chelates divalent cations in the solution preventing DNases from damaging the plasmid and also helps by destabilizing the cell wall. Glucose maintains the osmotic pressure so the cells don’t burst and RNase A is included to degrade cellular RNA when the cells are lysed.
3. Lysis
The lysis buffer (aka solution 2) contains sodium hydroxide (NaOH) and the detergent Sodium Dodecyl (lauryl) Sulfate (SDS). SDS is there to solubilize the cell membrane. NaOH helps to break down the cell wall, but more importantly it disrupts the hydrogen bonding between the DNA bases, converting the double-stranded DNA (dsDNA) in the cell, including the genomic DNA (gDNA) and your plasmid, to single stranded DNA (ssDNA). This process is called denaturation and is central part of the procedure, which is why it’s called alkaline lysis. SDS also denatures most of the proteins in the cells, which helps with the separation of the proteins from the plasmid later in the process.
It is important during this step to make sure that the re-suspension and lysis buffers are well mixed, although not too vigorously (see below). Also remember that SDS and NaOH are pretty nasty so it’s advisable to wear gloves and eye protection when performing alkaline lysis.
4. Neutralization
Addition of potassium acetate (solution 3) returns the pH to neutral. Under these conditions the hydrogen bonding between the bases of the single stranded DNA can be re-established, so the ssDNA can re-nature to dsDNA. This is the selective part. While it is easy for the the small circular plasmid DNA to re-nature it is impossible to properly anneal those huge gDNA stretches. This is why it’s important to be gentle during the lysis step because vigorous mixing or vortexing will shear the gDNA producing shorter stretches that can re-anneal and contaminate your plasmid prep.
While the double-stranded plasmid can dissolve easily in solution, the single stranded genomic DNA, the SDS and the denatured cellular proteins stick together through hydrophobic interactions to form a white precipitate. The precipitate can easily be separated from the plasmid DNA solution by centrifugation.
5. Cleaning and concentration
Now your plasmid DNA has been separated from the majority of the cell debris but is in a solution containing lots of salt, EDTA, RNase and residual cellular proteins and debris, so it’s not much use for downstream applications. The next step is to clean up the solution and concentrate the plasmid DNA.
There are several ways to do this including phenol/chloroform extraction followed by ethanol precipitation and affinity chromotography-based methods using a support that preferentially binds to the plasmid DNA under certain conditions of salt or pH, but releases it under other conditions.

Courtesy: Nick, BitesizeBio

The Best Way to Desalt DNA for Electroporation

After ligation, the method you use for desalting your sample prior to electroporation is critical, especially if your ligation is inefficient, according to a study by Schlaak et al [1].
Under standard electroporation conditions, the electric field of 12-18 kV/cm generated in a 0.1mm-gap electroporation cuvette means that the conductivity of the sample must be kept very low to prevent arcing. This means that any more than a very small amount of ligation mixture added to the competent cells will cause the sample to arc and the electroporation to fail.
So Schlaak et al looked at various methods of de-salting the DNA and compared how well the purified samples performed in electroporation. And their results were quite illuminating.
The experimental set-up was pretty simple. They took 1ng (high conc) or 3pg (low conc) intact pUC19 in 100ul of ligation reaction mix and desalted the samples using eitherethanol precipitation, gel filtration, drop dialysis or a commercial microcolumn(the type used for gel extraction/PCR cleanup), resuspending in a final volume of 50ul.
Then the resulting sample was used to transform 50ul of electrocompetent E.coli and the number of resulting colonies counted. Each experiment was performed in triplicate.

The Results…


As the table shows, for the high concentration samples the microcolumns were the clear winner, although dialysis and gel filtration gave just a 2-fold lower efficiency.
But the difference was more marked with the low concentration samples. Again, the microcolumns were the best, but this time they were at least 100x more efficient than any of the other methods.
For some reason, ethanol precipitation, a widely used method of desalting DNA, gave miserable results for both samples. It’s not clear whether this effect only occurs in the hands of these authors, or whether using a carrier would have helped (they didn’t). But it is certainly worth noting.
The take home message
For desalting 1ng or 3pg of intact plasmid, commercial microcolumns gave superior transformation efficiencies compared with the other methods.
The effect was far more obvious with 3pg of plasmid, which is worth noting, because many of the ligations you do will have DNA concentrations in this range.
So maybe using microcolumns for desalting your ligation mixes could improve your results…
If you give it a try, let us know how it goes.
Reference
1. Schlaak et al Biotechnology Letters (2005) 27:1003-1005

Courtesy: Nick, BitesizeBio

Saturday, April 18, 2009

The Basics: How Phenol Extraction Works

Phenol extraction is a commonly used method for removing proteins from a DNA sample, e.g. to remove proteins from cell lysate during genomic DNA preparation. It’s commonly used, but not commonly understood.

If you want to know how it works so you can show off to all of your friends… read on.

The basic protocol

I’ll start with a quick outline of how the procedure is performed. First, a volume of phenol is added to the aqueous soup containing the proteins and the DNA to be purified.

Since phenol and water are immiscible, two phases form - a water (a.k.a. aqueous) phase and a phenol phase. Phenol is the more dense of the two liquids so it sits on the bottom.

The phases are then mixed thoroughly. This forces the phenol into the water layer where it forms an emulsion of droplets throughout. The proteins in the water phase are denatured and partition into the phenol, while the DNA stays in the water.

The mixture is then centrifuged and the phases separate. The DNA-containing water phase can now be pipetted off, and the phenol/protein solution is discarded. Commonly, the DNA is then de-salted and concentrated using ethanol precipitation.

First, a bit about solvents

To explain how the addition of phenol can separate DNA and proteins, we need to briefly touch on solvents. This is the chemistry bit… bear with me.

phenol-water-polarity.gifA solvent is a substance, normally a liquid, that can dissolve other substances. Broadly, solvents can be classified according to their polarity, which depends on how extreme the spread of the electron density in the molecule is.

Water is a very polar solvent because the oxygen atom is very electronegative so it “sucks” the electrons towards it and away from the hydrogens, creating a slight negative charge on the oxygen and a slight positive on the hydrogens. i.e. the charge is “polarised” within the molecule.

Phenol is a less polar molecule than water. Although it has a highly electronegative oxygen, this is counteracted by the phenyl ring, which is also very electronegative so there is no concentration of electron density around the oxygen. i.e. the charge is not so polarised in a phenol molecule.

DNA is most soluble in the water phase

So what does this have to do with the separation of DNA and protein?

Well in general, polar (charged) compounds dissolve best in polar solvents and non-polar molecules dissolve best in less polar or non-polar solvents.

DNA is a polar molecule due to the negative charges on it’s phosphate backbone, so it is very soluble in water and less so in phenol. This means that when the water(+DNA +protein) and phenol are mixed in the protocol, the DNA does not dissolve in the phenol, but remains in the water phase.

phenol-ext1.gifThe solubility of the proteins is flipped by phenol

But, proteins are a different story entirely.

As you know proteins are made up of long chains of amino acids. Each amino acid has it’s own characteristics, due to the nature of their side chains. Some, (e.g. phenylalanine, leucine, and tryptophan) are non-polar, because their side chains contain no charged entities. Conversely, amino acids with side chains containing charged entities (e.g. glutamate, lysine and histidine) are polar.

The polarity differences in the side chains are biologically important because they largely determine how peptides fold into functional proteins. Put simply, the chains fold so that as many as possible of the side chains that are less polar than the solvent are on the inside of the proteins (away from the solvent), while those that are of similar polarity to the solvent are arranged on the outside of the proteins (see panel 1 in the figure above). Another way to think about it is that polar side chains are hydrophilic, and non-polar are hydrophobic. The hydrophobic side chains hide on the inside, with the hydrophilic chains on the outside.

In the cell (and note, I am talking about cytoplasmic proteins here), the proteins are folded according to the influence of water as the solvent, but when the proteins are exposed to a less polar solvent, like phenol, their folding changes (see panel 2 in the figure).

Basically, the proteins flip inside-out. The less-polar residues, which hid inside the protein structures in water, now want to interact with the less-polar phenol so are forced to the outside. Conversely, some of the very polar residues may flip to the inside of the globular protein to be shielded from the unsuitable new solvent.

In short the proteins are permanently denatured by the new solvent environment provided by the phenol.

Whereas in water the polar residues on on the outside of the proteins made them soluble in water, the phenol-induced folding changes forced the phenol-favoring residues to outside so that the proteins are now more more soluble in phenol than in water.

And this is the basis of the separation. The phenol-soluble proteins partition to the phenol phase while, as discussed above, the water soluble, polar DNA molecules stay in the water phase (see panel 3 in the figure).

So that’s how phenol extraction works. If you have any questions, or corrections, be sure to let me know.

Courtesy: Nick, BitesizeBio